1 SURFACE PREPARATION

TECNOPOL finishes for flat roofs and terraces can be applied on a wide range of existing surfaces (mortar, cement, traditional waterproof sheeting, ceramics, wood etc), using a few simple steps.

2. PRIMER

First apply a coat of primer resin to ensure maximum adhesion to the surface.[product primer-pu-1050]

3. WATERPROOFING MEMBRANE

Depending on the system chosen a membrane from either the DESMOPOL or TECNOCOAT range will be used.

4. FINISH LAYER

The TECNOPOL finishing coat consists of an aliphatic polyurethane resin, highly resistant to UV rays and hard wearing (can be walked on), and to which an anti-slip finish may also be added (conforms to CTE DB SUA, Class 3 classification (Rd >45), according to UNE-ENV 12633:2003).

Ceramic covered terrace

Sistema acabado cerámico

1. SURFACE PREPARATION

Ceramic finish flat roof flooring can be applied on whole wide range of existing surfaces (mortar, cement, traditional waterproof sheeting, acrylic paint, existing ceramic paving, wood etc).

2. PRIMER

First apply a coat of primer resin to ensure maximum adhesion to the surface.

3. WATERPROOFING MEMBRANE

Depending on the system chosen a membrane from either the DESMOPOL or TECNOCOAT range will be used.

4. MECHANICAL FIXING

To improve adhesion of the mortar and facilitate the positioning of the final paving, an anchoring coat should be first applied by sprinkling dry silica over a fine layer of polyurethane resin.

5. FINISH LAYER

The finishing layer of ceramic material will be positioned directly on top of the anchoring coat.

Plot paving

suelo técnico plots

1. SURFACE PREPARATION

Our finishes for raised flooring on roofs and terraces (using individual pieces positioned directly over the surface or via bases or pedestals) can be applied on a wide range of existing surfaces (mortar, cement, traditional waterproof sheeting, ceramics, wood etc).

2. PRIMER

First apply a coat of primer resin to ensure maximum adhesion to the surface.

3. WATERPROOFING MEMBRANE

Depending on the system chosen a membrane from either the DESMOPOL or TECNOCOAT range will be used.

4. FINISH LAYER

The raised flooring finish will then be positioned directly over the waterproofing membrane.

Flat roofs for vehicle traffic

tráfico rodado

1. SURFACE PREPARATION

Our finishes for flat roofs designed for vehicle traffic can be applied on a wide range of existing surfaces, typically concrete, using a simple preparation process, and are designed to meet aesthetic demands as well as waterproofing considerations.

2. PRIMER

A primer resin should be first applied to ensure adhesion to the surface.

3. WATERPROOFING MEMBRANE

The TECNOCOAT waterproof membrane is applied directly over the primer resin.

4. FINISH LAYER

The finishing coat consists of an aliphatic resin, highly resistant to UV rays and hard wearing (can be walked on), and to which an anti-slip finish may also be added (conforms to CTE DB SUA, Class 3 classification (Rd >45), according to UNE-ENV 12633:2003)..

TECNOFOAM inverted flat roofs

cubierta invertida tecnofoam

Flat roofs with thermal insulation based on TECNOFOAM polyurethane foam applied to the outside of the system are known as “inverted”. These offer a simple and effective solution solely requiring protection for the foam from UV rays which would otherwise degrade the aromatic material.

1. SURFACE PREPARATION

Finishes for flat roofs with thermal insulation based on TECNOFOAM polyurethane foam may be applied on a wide range of existing surfaces (mortar, cement, traditional waterproof sheeting, ceramics, wood etc), using a few simple steps.

2. PRIMER

First apply a coat of primer resin to ensure maximum adhesion to the surface.

3. WATERPROOFING MEMBRANE

Depending on the system chosen a membrane from either the DESMOPOL or TECNOCOAT range will be used.

4. ISOLATION LAYER

The coat of TECNOFOAM poyurethane foam is applied directly onto the membrane before it has completely polymerized.

5. FINISH LAYER

For UV ray protection a final coat should be applied using a highly resistant aliphatic polyurethane resin.

Traditional inverted flat roofs

cubierta invertida tradicional

Flat roofs with thermal insulation (in this case polystyrene panels) located on the outside of the system are known as “inverted”. These offer a simple and effective solution where one simply needs to take extra care with the ballasting given that mechanical attachment will not be possible as this type of flooring is positioned on top of the waterproof membrane.

1. SURFACE PREPARATION

Ballasted flat flooring with thermal insulation may be applied on a wide range of existing surfaces (mortar, cement, traditional waterproof sheeting, ceramics, wood etc.), using a few simple steps.

2. PRIMER

First apply a coat of primer resin to ensure maximum adhesion to the surface.

3. WATERPROOFING MEMBRANE

Depending on the system chosen a membrane from either the DESMOPOL or TECNOCOAT range will be used.

4. ISOLATION LAYER

The polystyrene panels are positioned directly over the membrane, taking care to ensure they are correctly overlapped and fitted.

5. Ballast layer

To ensure correct positioning of polystyrene panels these should be ballasted with, for example, dry aggregates.

Fifth facade

sistema quinta cubierta

Our liquid and continuous waterproofing systems provide the ideal solution for ensuring continuity with the other vertical facades usually produced using continuous mortar, offering both functionality and a consistent aesthetic finish.

1. SURFACE PREPARATION

The procedure will consist of first ensuring correct preparation to ensure a good initial appearance of the surface, typically made of concrete, bearing in mind that the final aesthetic finish is a key element of the process.

2. PRIMER

First apply a coat of primer resin to ensure maximum adhesion to the surface

3. WATERPROOFING MEMBRANE

Depending on the system chosen a membrane from either the DESMOPOL or TECNOCOAT range will be used.

4. FINISH LAYER

The TECNOPOL finish consists of an aliphatic polyurethane resin, highly resistant to UV rays and hard wearing (can be walked on), which is applied using either airless equipment or a roller.

Garden area roofs & flooring

cubierta ajardinada

1. SUPPORT PREPARATION

Finishes designed for garden area roofs and flooring may be applied on a wide range of existing surfaces (mortar, cement, traditional waterproof sheeting, ceramics, wood etc.)

2. PRIMER

First apply a coat of primer resin to ensure maximum adhesion to the surface.

3. WATERPROOFING MEMBRANE

Depending on the system chosen a membrane from either the DESMOPOL or TECNOCOAT range will be used.

4. FINISH LAYER

The company responsible for the design and style of the gardened roof area will need to decide on the various additional coats required for this type of finish.

 

cubierta obra nueva 1cubierta obra nueva 2cubierta obra nueva 3cubierta obra nueva 4cubierta obra nueva 5cubierta obra nueva 6cubierta obra nueva 7cubierta obra nueva 8cubierta obra nueva 9cubierta obra nueva 10cubierta obra nueva 11cubierta obra nueva 12cubierta obra nueva 13cubierta obra nueva 14cubierta obra nueva 15cubierta obra nueva 16